Automatic Microscale Continuously Closed Cup Flash Point Analyzer
Automatic Microscale Continuously Closed Cup Flash Point Analyzer
Description
Under specified test conditions, when a sample is heated to the temperature called flash point, the sample vapor and air mixture are ignited instantly. Flash point is one of the indicators for the evaluation of a material's combustion tendency. If the flash point Is low, the combustion risk would be high. As for transport and safety regulations, flash point is used for the classification of "flammable liquids". Also, flash point is used for quality control index or determining the existence of highly volatile or flammable substances in relatively nonvolatile or nonflammable matter, e.g. lubricant mixed with a small amount of diesel or gasoline.
Features
Fully Automatic
- Automatic determination of flash points
- Automatic corrections for ambient atmospheric
Small Sample Size
- Required amount of sample for each test is 1 mL or 2 mL
- Less sample demand, lower test cost and less pollution
High Performance
- Continuously closed cup operation with high safety and no open flame
- Built-in refrigeration module with high efficiency
Industrial Touch Screen User Interface
- 7-inch Integrated Color Touch Screen
- Built-in standard test methods which can be correlated to other closed cup methods
- Real-time display of temperature and pressure curves
USB and Network Connections
- RS232 interface for connection to thermal printer
- USB interface for connection with mouse or storage device
- Internet (Ethernet) connection
Software Capabilities
- Preprogrammed methods - each with its own interface
- User friendly, easily toggle between parameter view and graphic view
- When the expected flash point is entered, the initial and end temperatures are automatically calculated
Specifications
Conforms to the specifications of: ASTM D6450 and D7094
Excellent Correlation to: ASTM D56, D93, D3278, D3828; IP 170; EN ISO 6379 / 3680; ISO 2719; SH/T 0768, SH/T 3077.1, SH/T 3077.2, DL/T 1354, GB/T 261, GB/T 21615, GB/T 5208, GB/T 21790
Temperature Range: -30 °C to 405°C (-22 °F to 788 °F); below 0 °C an external cryogenic recirculatory is required
Heating Rate: 2.5 °C/min ± 0.3 °C/min or 5.5 °C/min ± 0.5 °C/min; can be customized in the range of 0.5 to 12 C/min
Temperature Accuracy: ± 0.1 °C
Pressure Range: 0 kPa to 200 kPa
Sample Volume: 1 mL or 2 mL
Ignition method: High voltage electric ignition
Stirring Rate: Can be customized from 50 RPM to 300 RPM
Interfaces: RS232, USB, Ethernet
K24880 - Automatic Microscale Closed Cup Flash Point Analyzer (Operational Video)